Standard leak hole, suitable for helium mass spectrometry vacuum leak detector, channel type open, positive pressure and negative pressure, leakage rate support customization, leakage rate range: 1x10-3Pam3/s ~ 5x10-10Pam3/s,
Straight-through helium standard leakage hole, 1 *10-3Pam3/s ~ 1 *10-7 Pam3/s large leakage rate standard leak hole. Seepage helium type standard leakage hole is not suitable for large leakage rate standard leakage hole because it will be seriously attenuated.Helium mass spectrometry leak detector using out-of-machine calibration if only -8 or -9 leak holes do not represent the large leakage rate of -4 and 5 is also accurate, Therefore, the external calibration needs to be calibrated at the same time as the standard leakage hole of the large leakage rate and the small leakage rate to ensure that the equipment is normal
Provide domestic ion source filament suitable for Agilent VS/HLD helium mass spectrometry leak detector, instead of R3428301applicable Agilent VS series HLD series:PR02PD03MR15MD30BR15BD30
domestic ion source filament 053146/053146Y, suitable for Pufa Alcatel helium mass spectrometry leak detector, new filament bracket, the same quality life, iridium gold filament 053146 life is far more than tungsten filament 053146, more economical and practical (see the photo of the physical object), suitable for Alcatel, Pufa, Zhongke instrument A wide range of helium mass spectrometry leak detectors, including: Alcatel, ADIXEN, Pufa various models of helium mass spectrometry leak detector ASM 142 / 142S / 142DASM 310ASM 380ASM 182 T / TD+ ASM 192 T / T2D+ASM 1002ASI 20ASI 30ASM 102 S
Zhongke instrument various helium mass spectrometry leak detector ZQJ-542GZQJ-542 delivery time commitment: SF within 24 hours of receiving the goods.
Quality commitment: the store's tungsten filament ion source and the original filament have the same quality and life, if there is a quality problem can be replaced within 30 days from the date of shipment with the parameter code and date code on the box, due to improper use or equipment problems caused by serious deformation of the filament and wire breakage is not within the scope of protection.
Standard leak hole, suitable for helium mass spectrometry vacuum leak detector, channel type open, positive pressure and negative pressure, leakage rate support customization, leakage rate range: 1x10-3Pam3/s ~ 5x10-10Pam3/s,
Straight-through helium standard leakage hole, 1 *10-3Pam3/s ~ 1 *10-7 Pam3/s large leakage rate standard leak hole. Seepage helium type standard leakage hole is not suitable for large leakage rate standard leakage hole because it will be seriously attenuated.Helium mass spectrometry leak detector using out-of-machine calibration if only -8 or -9 leak holes do not represent the large leakage rate of -4 and 5 is also accurate, Therefore, the external calibration needs to be calibrated at the same time as the standard leakage hole of the large leakage rate and the small leakage rate to ensure that the equipment is normal
Provide domestic ion source filament suitable for Agilent VS/HLD helium mass spectrometry leak detector, instead of R3428301applicable Agilent VS series HLD series:PR02PD03MR15MD30BR15BD30
domestic ion source filament 053146/053146Y, suitable for Pufa Alcatel helium mass spectrometry leak detector, new filament bracket, the same quality life, iridium gold filament 053146 life is far more than tungsten filament 053146, more economical and practical (see the photo of the physical object), suitable for Alcatel, Pufa, Zhongke instrument A wide range of helium mass spectrometry leak detectors, including: Alcatel, ADIXEN, Pufa various models of helium mass spectrometry leak detector ASM 142 / 142S / 142DASM 310ASM 380ASM 182 T / TD+ ASM 192 T / T2D+ASM 1002ASI 20ASI 30ASM 102 S
Zhongke instrument various helium mass spectrometry leak detector ZQJ-542GZQJ-542 delivery time commitment: SF within 24 hours of receiving the goods.
Quality commitment: the store's tungsten filament ion source and the original filament have the same quality and life, if there is a quality problem can be replaced within 30 days from the date of shipment with the parameter code and date code on the box, due to improper use or equipment problems caused by serious deformation of the filament and wire breakage is not within the scope of protection.