Provide domestic ion source filament suitable for Agilent VS/HLD helium mass spectrometry leak detector, instead of R3428301applicable Agilent VS series HLD series:PR02PD03MR15MD30BR15BD30
domestic ion source filament 053146/053146Y, suitable for Pufa Alcatel helium mass spectrometry leak detector, new filament bracket, the same quality life, iridium gold filament 053146 life is far more than tungsten filament 053146, more economical and practical (see the photo of the physical object), suitable for Alcatel, Pufa, Zhongke instrument A wide range of helium mass spectrometry leak detectors, including: Alcatel, ADIXEN, Pufa various models of helium mass spectrometry leak detector ASM 142 / 142S / 142DASM 310ASM 380ASM 182 T / TD+ ASM 192 T / T2D+ASM 1002ASI 20ASI 30ASM 102 S
Zhongke instrument various helium mass spectrometry leak detector ZQJ-542GZQJ-542 delivery time commitment: SF within 24 hours of receiving the goods.
Quality commitment: the store's tungsten filament ion source and the original filament have the same quality and life, if there is a quality problem can be replaced within 30 days from the date of shipment with the parameter code and date code on the box, due to improper use or equipment problems caused by serious deformation of the filament and wire breakage is not within the scope of protection.
Applicable to ZQJ-230D.230E.530.2000 leak detector.
There are 3 kinds of materials used in the filament, the first conventional material - the filament special tungsten filament (life is equivalent to the ordinary ion source of the original factory), the second material - the yttrium-plated tungsten wire (twice the life of the original tungsten filament, equivalent to the original yttrium plating ion source), the third material -Yttrium-plated iridium gold wire (independently developed, 10 times that of the original ordinary ion source). The original Zhongke Instrument ion source has no warranty (false one penalty ten).
If the ion source maintenance needs the original ion source filament rack to be sent over, we replace it with the new filament and ship it after passing the test.
Delivery time commitment: SF within 24 hours of receiving the goods.
Provide domestic ion source filament suitable for Agilent VS/HLD helium mass spectrometry leak detector, instead of R3428301applicable Agilent VS series HLD series:PR02PD03MR15MD30BR15BD30
domestic ion source filament 053146/053146Y, suitable for Pufa Alcatel helium mass spectrometry leak detector, new filament bracket, the same quality life, iridium gold filament 053146 life is far more than tungsten filament 053146, more economical and practical (see the photo of the physical object), suitable for Alcatel, Pufa, Zhongke instrument A wide range of helium mass spectrometry leak detectors, including: Alcatel, ADIXEN, Pufa various models of helium mass spectrometry leak detector ASM 142 / 142S / 142DASM 310ASM 380ASM 182 T / TD+ ASM 192 T / T2D+ASM 1002ASI 20ASI 30ASM 102 S
Zhongke instrument various helium mass spectrometry leak detector ZQJ-542GZQJ-542 delivery time commitment: SF within 24 hours of receiving the goods.
Quality commitment: the store's tungsten filament ion source and the original filament have the same quality and life, if there is a quality problem can be replaced within 30 days from the date of shipment with the parameter code and date code on the box, due to improper use or equipment problems caused by serious deformation of the filament and wire breakage is not within the scope of protection.
Applicable to ZQJ-230D.230E.530.2000 leak detector.
There are 3 kinds of materials used in the filament, the first conventional material - the filament special tungsten filament (life is equivalent to the ordinary ion source of the original factory), the second material - the yttrium-plated tungsten wire (twice the life of the original tungsten filament, equivalent to the original yttrium plating ion source), the third material -Yttrium-plated iridium gold wire (independently developed, 10 times that of the original ordinary ion source). The original Zhongke Instrument ion source has no warranty (false one penalty ten).
If the ion source maintenance needs the original ion source filament rack to be sent over, we replace it with the new filament and ship it after passing the test.
Delivery time commitment: SF within 24 hours of receiving the goods.